Environmental noise measurement

Noise is among the most common causes of neighbourhood complaints and among the parameters environmental permits routinely require. We measure with a Cirrus CR:831C Class I sound level meter — the highest accuracy class — across daytime, evening and night-time periods. Periodic noise testing in the living and working environment falls within the scope of our IT-127 accreditation to MKS EN ISO/IEC 17020:2012, Type A.

What the service covers

  • Noise level measurement during daytime, evening and night-time periods
  • Measuring points at the site boundary and at the nearest sensitive receptors
  • Determination of equivalent and maximum levels
  • Identification of the dominant noise source
  • Background level measurement with the source shut down, to isolate its contribution
  • Comparison against the area limit values by protection level
  • A report with measuring points, conditions and meteorological data
  • Proposed mitigation measures where limits are exceeded

This service falls within the scope of accreditation IT-127 to MKS EN ISO/IEC 17020:2012, Type A.

How the process works

  1. Selecting measuring points

    We select points at the site boundary and at the nearest sensitive receptors, based on the sources present.

  2. Measurement by period

    We measure during daytime, evening and night-time periods, as the limit values differ for each.

  3. Background level

    Where practicable we also measure with the source shut down, to separate your contribution from total noise.

  4. Report

    An accredited report with measuring points, conditions, meteorological data and a conclusion per point.

Frequently asked questions

Is noise measurement accredited?

Yes. Periodic noise testing in the living and working environment is within the scope of our accreditation IT-127 to MKS EN ISO/IEC 17020:2012, Type A, valid until 5 September 2029.

Why must measurement also be done at night?

Because the limit values are stricter at night, and that is when most complaints arise. Daytime-only measurement gives an incomplete picture and is not sufficient for proceedings.

What if the limits are exceeded?

The report states which source dominates and by how much the limit is exceeded. On that basis we propose technical measures — barriers, insulation, a change of operating regime or relocating the source.

Request a quote for this service

Describe the situation at your company and you will receive a specific quote with a delivery timeline.